INFO / WORKSITE LIGHTING REQUIREMENTS:
Allmand recommends that you understand the minimum lighting conditions that are required for your application. The table below details the OSHA requirements. Remember, using multiple light towers will help eliminate large shadows.
OSHA Regulation 1926.56(a)
General. Construction areas, ramps, runways, corridors, offices, shops, and storage areas shall be lighted to not less than the minimum illumination intenities listed in Table D-3 while any work is in progress:
TABLE D-3 - MINIMUM ILLUMINATION INTENSITIES
IN FOOT-CANDLES
FOOT-CANDLES AREA OF OPERATION
| 5.... | General construction area lighting |
| 3.... | General construction areas, concrete placement, excavation and waste areas, access ways, active storage areas, loading platforms, refueling, and field maintenance areas. |
| 5.... | Indoors: warehouses, corridors, hallways, and exitways. |
| 5.... | Tunnels, shafts, and general underground work areas: (Exception: Minimum of 10 foot-candles is required at tunnel and shaft heading during drilling, mucking, and scaling. Bureau of Mines approved cap lights shall be acceptable for use in the tunnel heading) |
| 10.... | General construction plant and shops (e.g., batch plants, screening plants, machanical and electrical equipment rooms, carpenter shops, rigging lofts and active store rooms, mess halls, and indoor toilets and workrooms.) |
| 30.... | First aid stations, infirmaries, and offices. |
|
|